The product is a mobile 3-wheeled electric scooter, model HMV 250. The product contains either a red or blue base. The r
FDA device recall Z-0522-06 · posted 2006-02-16 · Terminated
Recall details
- Recalling firm
- Tung Keng Enterprise Co., Ltd.
- Reason for recall
- The throttle spring, located in the hand throttle assembly, can fracture, resulting in the scooter not stopping when the user releases the throttle.
- Action taken
- The recalling firm sent field correction instructions to their customers on or about 11/1/05.
- Root cause
- Other
- Status
- Terminated
- Product code
- INI
- Quantity affected
- 8,213 total devices
- Distribution
- The product was distributed to OHL/Invacare, Rancho Technology Park Bldg. B 8950, Rancho Cucamonga, CA 91730; OHL/Invacare, 1100 Whitaker Road, Plainfield, IN 46168; Invacare Corporation, 39400 Taylor
- Date initiated
- 2005-11-01
- Date posted
- 2006-02-16
- Date terminated
- 2012-05-08
- Location
- Hsiang Taichung County, Taiwan