Access Immunoassay Systems enhanced AccuTnl Reagent Kit, Part Number: A78803 The Access Accu Tri assay is a paramagnetic
FDA device recall Z-1883-2011 · posted 2011-04-04 · Terminated
Recall details
- Recalling firm
- Beckman Coulter Inc.
- Reason for recall
- The recall was initiated after Beckman Coulter confirmed that under certain circumstances, the following assays may produce elevated values at the low end when run in conjunction with the enhanced Access Accu Tnl assay (P/N A 78033): (1) Access Total BhCG (P/N 33500); (2) Access HYPERsensitive hTSH/Fast hTSH (P/N 33820); (3) Access hFSH (P/N 33520). The issue can occur only when the assays are
- Action taken
- The firm, Beckman Coulter, sent an "URGENT: PRODUCT CORRECTIVE ACTION" letter dated December 16, 2009 to all customers. The letter described the product, problem and actions to be taken. Beckman Coulter instructed the customers to do the following mitigation to reduce the risk of encountering an erroneous result: Systems with multiple reagent pipettors (UniCel Dxl 800 and 600; UniCel DxC 880i, 860i, 680i, and 660i): 1. Designate enhanced Access AccuTnl to a different reagent pipettor (s) than Access Total BhCG/Dil-hCG2, hTSH/Fast hTSH and hFSH. 2. Discard any open Access Total BhCG, hTSH/Fast hTSH and hFSH reagent packs 3. Calibrate Access Total BhCG, hTSH and hFSH using fresh reagent packs 4. Run QC following acceptable calibration curves. Proceed with operation following acceptable QC performance Systems without multiple reagent pipettors (Access, Access 2; SYNCHRON LXi 725, UniCel DxC 600i): 1. Discard any open Access Total BhCG, hTSH/Fast hTSH and hFSH reagent packs. 2. Calibrate Access Total BhCG, hTSH/Fast hTSH and hFSH using fresh reagent packs 3. Run QC following acceptable calibration curves. Ensure that controls and patient samples for Access Total BhCG/Dil-hCG2, hTSH/Fast hTSH and hFSH are not run immediately following enhanced Access AccuTnl controls or patient samples. For example, during routine QC runs, ensure that these assays are requested prior to enhanced Access AccuTnl. 4. Proceed with operation following acceptable QC performance. NOTE: An enhanced AccuTnl sample loaded with a system priority of STAT will interrupt routine Total BhCG/Dil-hCG2, hTSH/Fast hTSH and hFSH sample aspiration. Avoid loading enhanced AccuTnl sample aspiration. Avoid loading enhanced AccuTnl samples with a system priority of STAT during aspiration of Total BhCG/Dil-hCG2, hTSH/Fast hTSH and hFSH. Diagnostic test results should be interpreted in light of the clinical presentation of the patient, including: symptoms, clinical history, data from other
- Root cause
- Other
- Status
- Terminated
- Product code
- MMI
- Quantity affected
- 22,032 kits
- Distribution
- Worldwide distribution: USA and country of Canada.
- Date initiated
- 2009-12-10
- Date posted
- 2011-04-04
- Date terminated
- 2012-05-07
- Location
- Brea, CA
Monitor recalls programmatically
Recalls and clearances share one API, with change alerts when new recalls post.
Related 510(k) clearances
| Record | Firm | Date |
|---|---|---|
| ACCUTNI AND ACCUTNI CALIBRATORS ON THE ACCESS IMMUNOASSAY SYSTEMS, MODEL #33340, 33345 (K021814) | Beckman Coulter, Inc. | 2002-09-27 |
| ACCUTNI AND ACCUTNI CALIBRATORS ON THE ACCESS IMMUNOASSAY SYSTEM # 33340, 33345 (K010429) | Beckman Coulter, Inc. | 2001-06-05 |